110924 HEATH Version: 1, February 1989
Submitted by: John M. Crowell, Davis, CA
Operating System: RT-11 V5.5 Source Language: MACRO-11 Memory
Required: 8KB Hardware Required: Heathkit Model GC1000 Digital Clock
and DL11-Type Serial Port Keywords: Clock, Heath-11
Abstract: This program sets the RT-11 date and time from the ASCII
string produced by the Heathkit GC1000 WWV clock connected
to a DL11 type serial port. It may be run from a startup
command file to set the system date and time at bootstrap.
Notes: Executable and/or object code is included.
Restrictions: Operating System RT-11 V5.0 or later is required.
Media (Service Charge Code): One RX50 Diskette (JA) Format: RT-11,
One RX01 Diskette (KA) Format: RT-11
The PDP-11 DECUS Software Index
The PDP-11 Home Page
Tim Shoppa
<shoppa@trailing-edge.com>